5G UPGRADE – Structural Reinforcement

AB, Canada

 

To support the integration of new 5G antennas, RRUs, DC/FO routing, pinwheel reinforcement, and mid-panel horizontals
on an existing 103.2 m guyed mast tower. To propose new strengthening design.

5G UPGRADE – Structural Reinforcement

CHALLENGES

Strengthening required for tower legs under new 5G loads
Solution: Site audit to capture all missing measurements
Impact: Enabled accurate assessment

Existing antenna pipes too short
Solution: Replaced with longer HSS73 members
Impact: Correct antenna spacing and alignment ensured

Structural congestion at 101.5 m due to high mounting density
Solution: Designed multi-level pinwheel reinforcement
Impact: Improved structural stability

Future RRUs & antennas increasing loads
Solution: Included future loading in analysis
Impact: Enhanced long-term structural stability and durability

TECHNICAL HIGHLIGHTS

Technologies: 4G/5G

Tools & Platforms: AutoCAD

Innovations / Optimizations: New strengthening proposed

Key Metrics: Reinforcement design across multiple tower elevations, ensuring compliance with CSA S37 code, with strengthened detailing proposed for improved long-term structural durability

DELIVERABLES

  • Construction drawing package, including full structural reinforcement design for 66.73–83.1 m and complete strengthening detailed drawings

Key Highlights:

103.2m

Tower height assessed for reinforcement

16.37m

Structural strengthening zone designed

03

Engineering challenges resolved

4G/5G

Multi-technology upgrade supported

CSA S37

Canadian structural compliance achieved

100%

Future load capacity considered in design

CONCLUSION

Our solutions added real value by improving safety, durability, and upgrade readiness. The project was delivered with precise assessments and smart, practical engineering decisions

We’re ready to apply the same expertise and thoughtful problem-solving to your next project.